Description
Installation Instructions
To install a hard drive into the OE274 Dell SCSI hot-swap hard drive sled tray bracket, follow these steps:
- Power off the server and unplug it from the power source
- Open the server chassis and locate an empty drive bay
- Remove the blank filler panel from the bay
- Slide the OE274 sled tray into the bay until it clicks into place
- Connect the hard drive to the sled tray using the SCSI data and power cables
- Close the server chassis and plug the server back into the power source
- Power on the server and allow it to recognize the new drive
Note: It is important to follow the manufacturer’s guidelines and safety procedures when performing any maintenance on a server. Make sure to handle the hard drive with care to avoid damage.
Maintenance of Hot Swap
To perform maintenance on the OE274 Dell SCSI hot-swap hard drive sled tray bracket for PowerEdge or PowerVault servers, follow these steps:
- Power off the server and unplug it from the power source
- Open the server chassis and locate the drive sled tray
- Press the release button on the tray to eject it from the bay
- Remove the hard drive from the tray by releasing the drive’s retention mechanism
- Install a replacement drive onto the tray by securing it to the retention mechanism
- Slide the tray back into the bay until it clicks into place
- Connect the SCSI data and power cables to the new drive
- Close the server chassis and plug the server back into the power source
- Power on the server and allow it to recognize the new drive
Note: It is recommended to follow the manufacturer’s guidelines and safety procedures when performing any maintenance on a server. It is also important to ensure that the replacement hard drive is compatible with the server and sled tray before installing it.
Troubleshooting
To troubleshoot issues with the OE274 Dell SCSI hot-swap hard drive sled tray bracket for PowerEdge and PowerVault servers, try the following steps:
- Check the data cables: Ensure that the data cables are properly connected to the hard drive and the server motherboard.
- Verify power supply: Make sure that the power cables are connected to the hard drive and the server power supply.
- Check the drive status: In the server management software, check the status of the hard drive and see if it is recognized by the server.
- Update firmware: If the hard drive is not recognized by the server, try updating the server firmware and the hard drive firmware to the latest version.
- Re-install the hard drive: If the previous steps do not resolve the issue, try re-installing the hard drive into the OE274 sled tray.
- Check the compatibility: Verify that the hard drive is compatible with the OE274 sled tray and the server.
- Contact technical support: If the issue persists, contact Dell technical support for assistance. Provide the model and serial numbers of the server and the hard drive, as well as a detailed description of the issue.
General Information
- Part No: OE274
- Manufacturer : Dell
Compatibility
- Poweredge 700, 800, 1600, 1600SC, 1800, 1850, 2600, 2650, 2800, 2850, 3250, 6600, 6650, 6800, 6850, 7150, Series Servers And Powervault 220s, 221s, 220f, 650f, 660f Scsi Arrays
Key Features
- Cabinet Type : Internal Drive Case
Storage Controllers
- Supported Devices : Hard Drive